ID #1024

When use S30interface script to configure an additional VIP, does RSF-1 monitor this network interface? And if this interface fails, does this trigger a fail over?

RSF-1 monitors the physical interface state (if configured to do so) and as a by product any VIP's bound to that interface are therefore also monitored. When interface monitoring is configured, any services that use that physical interface are considered dependants, and as such should the interface fail, then those services are marked as potential for fail over (dependant on other factors such as the secondary node being in a position to accept the service - a dependency which also includes the monitoring the health of it's own network physical interface that the service will use).

The S30interface script is used to configure additional VIP's for a service (on the physical interface declared in the configuration file for that service) so yes if an interface fails, and RSF-1 is configured to monitor network interfaces (and the S30interface scripts places additional interfaces on the *same* interface configured for the service) then if the interface fails RSF-1 will fail over the service and as such any additional VIP's bound on that interface (note! the corresponding S30interface script should exist on the node being failed over to to ensure the additional VIP is configured for the service).

If the S30interface scripts places additional VIP's on interfaces that RSF-1 has no knowledge of (for example the service uses hme0, but S30interface plumbs in an additional interface, bge0, then there is no way of RSF-1 knowing about (and therefore monitoring) this additional  interface.

Tags: -

Related entries:

Last update: 2009-09-11 10:48
Author: Paul Griffiths
Revision: 1.1

{writeDiggMsgTag} {writeFacebookMsgTag} {writePrintMsgTag} {writeSend2FriendMsgTag} {writePDFTag}